CONSTRUCTIONS
by AiXLuxury
HOME/KNOWLEDGE/MATERIALS/ROCK MINERAL WOOL INSULATION
Thermal & Acoustic InsulationSTATUS: VERIFIEDTIER: TIER 1 (Official Standard / Eurocode)

Rock Mineral Wool Insulation

Romanian Technical Denomination: Vată Minerală Bazaltică

Non-combustible stone wool insulation produced from volcanic basalt rock, delivering Class A1 fire protection, thermal insulation, and sound absorption.

LEVEL 1: QUICK UNDERSTANDING (EXECUTIVE SUMMARY)

INVESTORS & DEVELOPERS
What is it?

Non-combustible stone wool insulation produced from volcanic basalt rock, delivering Class A1 fire protection, thermal insulation, and sound absorption.

Where is it used?

Ventilated facade insulation and high-rise ETICS building envelopes, Fire-rated perimeter bands (brâuri rezistente la foc) in EPS facade systems

01. TECHNICAL OVERVIEW & ENGINEERING CHARACTERISTICS

Rock Mineral Wool compliant with SR EN 13162:2015. Manufactured by spinning molten volcanic basalt rock at 1500°C into fine fibrous mats bonded with thermosetting resins. Delivers Euroclass A1 non-combustibility (melting point > 1000°C), superior acoustic sound absorption, high vapor breathability (μ = 1), and thermal conductivity of 0.034-0.038 W/mK. Mandated for ventilated facades, tall buildings, and fire barriers under Romanian Normativ P118/2.

02. CONSTITUENTS & MANUFACTURING SPECIFICATION

  • ▸Volcanic basalt rock, dolomite, and bauxite melted in cupola furnaces at 1500°C
  • ▸Centrifugal fiber spinning with water-repellent (hydrophobic) additives and organic binders

✓ ADVANTAGES & STRENGTHS

  • •Completely non-combustible (Class A1), acting as a fire barrier that prevents vertical flame spread
  • •Outstanding acoustic sound attenuation (airborne and impact sound absorption)
  • •Maximum water vapor permeability (μ = 1), completely eliminating risk of interstitial condensation in breathable walls
  • •Dimensional stability immune to thermal expansion or contraction

⚠ LIMITATIONS & RISK FACTORS

  • •Higher weight (80-150 kg/m³ for facade boards) requiring heavy-duty mechanical anchor dowels
  • •Higher material and installation cost compared to standard EPS
  • •Must be protected from continuous liquid water soaking during on-site storage and installation

03. ARCHITECTURAL & STRUCTURAL USE CASES

Ventilated facade insulation and high-rise ETICS building envelopes
Fire-rated perimeter bands (brâuri rezistente la foc) in EPS facade systems
Acoustic partition walls and intermediate concrete floor soundproofing
Flat roof thermal insulation under single-ply or bituminous waterproofing

PHYSICAL & MECHANICAL PROPERTIES

STANDARDIZED
Thermal Conductivity (λD)VERIFIED
0.034 - 0.038 W/(m·K)
Ref: SR EN 13162
Reaction to FireVERIFIED
Class A1 (Non-combustible)
Ref: SR EN 13501-1
Melting Point TemperatureVERIFIED
> 1000 °C
Ref: DIN 4102-17
Water Vapor Diffusion Coefficient (μ)VERIFIED
1 (Open to diffusion) dimensionless
Ref: SR EN 12086
Tensile Strength Perpendicular to Faces (TR for Facade)VERIFIED
≥ 7.5 - 15 kPa
Ref: SR EN 1607

GOVERNING NORMATIVES & EUROCODES

§SR EN 13162:2015
§Normativ P118/2 (Romanian Fire Code)
§Normativ C 107
SOURCE TRUTH & VERIFICATION
Primary Ref: SR EN 13162:2015 & Romanian Fire Normativ P118/2
Verified Date: 2026-03-01
Hierarchy: TIER 1 (Official Standard / Eurocode)
← RETURN TO MATERIALS CATALOG