CONSTRUCTIONS
by AiXLuxury
HOME/KNOWLEDGE/MATERIALS/ALUMINIUM CURTAIN WALL & UNITIZED FACADE SYSTEMS
Facade Systems & EnvelopesSTATUS: VERIFIEDTIER: TIER 1 (Official Standard / Eurocode)

Aluminium Curtain Wall & Unitized Facade Systems

Romanian Technical Denomination: Fațade Cortină din Aluminiu și Sticlă

Non-structural exterior building envelope system hung from floor slabs, comprising extruded aluminium mullions/transoms and insulated glass units.

LEVEL 1: QUICK UNDERSTANDING (EXECUTIVE SUMMARY)

INVESTORS & DEVELOPERS
What is it?

Non-structural exterior building envelope system hung from floor slabs, comprising extruded aluminium mullions/transoms and insulated glass units.

Where is it used?

Class A commercial office high-rises and institutional headquarters, Mixed-use luxury residential towers and hotel facades

01. TECHNICAL OVERVIEW & ENGINEERING CHARACTERISTICS

Curtain walling systems engineered in accordance with SR EN 13830:2015. Available as stick-built systems (montanți și rigle) or prefabricated unitized elements (elemente vitrate modulare). Designed to resist positive/negative wind pressures (up to 2400 Pa), dynamic water penetration, inter-story seismic building drift (P100-1), and thermal expansion.

02. CONSTITUENTS & MANUFACTURING SPECIFICATION

  • ▸Extruded structural aluminium alloy EN AW-6060 / 6063 T6 profiles with thermal break polyamide bars (24-54mm)
  • ▸High-performance triple-glazed insulating units with Low-E and solar control coatings
  • ▸EPDM perimeter weather seals and pressure plates

✓ ADVANTAGES & STRENGTHS

  • •Maximizes natural daylight penetration and panoramic exterior views
  • •Unitized systems enable rapid off-site quality assembly and high-speed crane installation without external scaffolding
  • •Engineered expansion joints accommodate seismic inter-story drifts without glass fracture

⚠ LIMITATIONS & RISK FACTORS

  • •High capital expenditure per square meter of building envelope
  • •Requires careful solar control glass specification (g-value ≤ 0.35) to avoid excessive summer cooling loads and indoor glare
  • •Demands specialized periodic facade maintenance and exterior window cleaning cradles (BMU systems)

03. ARCHITECTURAL & STRUCTURAL USE CASES

Class A commercial office high-rises and institutional headquarters
Mixed-use luxury residential towers and hotel facades
Airport terminals and public transit hubs

PHYSICAL & MECHANICAL PROPERTIES

STANDARDIZED
Air PermeabilityVERIFIED
Class AE (up to 600 Pa)
Ref: SR EN 12152
Watertightness under Dynamic PressureVERIFIED
Class RE 1200 (1200 Pa)
Ref: SR EN 12154
Resistance to Wind LoadVERIFIED
2400 Pa design / 3600 Pa safety
Ref: SR EN 13116
Overall System Thermal Transmittance (Ucw)VERIFIED
0.80 - 1.20 W/(m²·K)
Ref: SR EN ISO 12631
Acoustic Attenuation (Rw + Ctr)VERIFIED
38 - 45 dB
Ref: SR EN ISO 10140

GOVERNING NORMATIVES & EUROCODES

§SR EN 13830:2015
§SR EN 14351-1
§Normativ C 107
§P100-1/2013
SOURCE TRUTH & VERIFICATION
Primary Ref: SR EN 13830:2015 Curtain Walling Product Standard
Verified Date: 2026-03-01
Hierarchy: TIER 1 (Official Standard / Eurocode)
← RETURN TO MATERIALS CATALOG