CONSTRUCTIONS
by AiXLuxury
HOME/KNOWLEDGE/TECHNICAL GLOSSARY
TECHNICAL DICTIONARY (30 TERMS)•REGULATORY & STRUCTURAL DEFINITIONS

CONSTRUCTION & URBAN PLANNING GLOSSARY

Standardized architectural, structural, and regulatory definitions. Clarifies essential abbreviations (POT, CUT, RH, AC), building physics metrics (U-value, thermal bridges), and Romanian construction law frameworks (Legea 50/1991, Legea 10/1995).

ENERGY & BUILDING PHYSICSVERIFIED

U-value (Coeficient de Transfer Termic U)(Thermal Transmittance (W/m²·K))

RO: Coeficient de Transfer Termic (U)

The rate of heat transfer through one square meter of a building element (wall, roof, window, slab) divided by the temperature difference across the element. Measured in W/(m²·K). Lower U-values indicate superior thermal insulation.

Practical Application:

Romanian nZEB regulations (Normativ C 107) enforce maximum permissible U-values: exterior walls U ≤ 0.18 - 0.20 W/m²K, flat roofs U ≤ 0.12 - 0.15 W/m²K, windows Uw ≤ 0.85 - 1.10 W/m²K.

Legal Ref: Normativ C 107/2005 & Legea 372/2005 privind performanța energetică a clădirilor (nZEB)
ENERGY & BUILDING PHYSICSVERIFIED

Thermal Bridge (Punte Termică)(Punte Termică Liniară / Punctuală)

RO: Punte Termică

A localized area of a building envelope where the thermal resistance is significantly lower than the surrounding wall, typically occurring at reinforced concrete column-slab intersections, balcony penetrations, and window frame perimeters.

Practical Application:

Thermal bridges lead to localized interior surface cooling, high winter heat loss, condensation risk, and toxic mold growth. Mitigated through continuous exterior insulation (ETICS) and structural thermal break balcony connectors (Isokorb).

Legal Ref: Normativ C 107/2-2005 & SR EN ISO 14683
ENERGY & BUILDING PHYSICSVERIFIED

Vapor Barrier (Barieră Contra Vaporilor)(Barieră de Vapori cu Rezistență Ridicată (Sd > 100m))

RO: Barieră de Vapori

A low-permeability membrane installed on the warm interior side of thermal insulation to prevent warm, humid indoor air from penetrating into the insulation layer and condensing into liquid water.

Practical Application:

Mandatory in flat roofs, timber frame walls, and attic ceilings.

Legal Ref: Normativ C 107 & SR EN 13984
ENERGY & BUILDING PHYSICSVERIFIED

nZEB (nearly Zero-Energy Building)(Clădire cu Consum de Energie Aproape Zero)

RO: Clădire nZEB

A building that has a very high energy performance, with near-zero energy demand covered to a very significant extent by energy from renewable sources produced on-site or nearby.

Practical Application:

Mandatory by law in Romania for all newly constructed buildings since January 1, 2021.

Legal Ref: Directiva EPBD & Legea 372/2005 (republicată)
ENERGY & BUILDING PHYSICSVERIFIED

ETICS (External Thermal Insulation Composite System)(Sistem Compozit de Izolare Termică la Exterior)

RO: Termosistem ETICS

A factory-specified kit comprising insulation boards (EPS, Rock Wool), adhesive, mechanical anchor fixings, basecoat reinforced with fiberglass mesh, and decorative finish render.

Practical Application:

Standard exterior thermal envelope solution in Romania.

Legal Ref: EAD 040083-00-0404 & Normativ C 107
ENERGY & BUILDING PHYSICSVERIFIED

Airtightness & Blower Door Test (Etanșeitate la Aer n50)(Testul de Presurizare / Depresurizare Blower Door)

RO: Etanșeitate la Aer (n50)

Building envelope airtightness measurement quantifying the air change rate at 50 Pascal pressure differential (n50 in h⁻¹).

Practical Application:

Ensures controlled ventilation performance and eliminates unconditioned draft heat losses in nZEB buildings (n50 ≤ 1.5 h⁻¹).

Legal Ref: SR EN ISO 9972 & Normativ C 107